Issues

Search

Home > Issues > Retrieve

Selection of Contactless-Power-Supply Housing Material Considering Eddy Current Loss, Thermal Load, and Structure Safety

Journal of Magnetics, Volume 23, Number 1, 31 Mar 2018, Pages 86-92
Phuong Thi Luu (University of Science and Technology), Jiyoung Lee * (University of Science and Technology), Jeongwook Lee (Korea Electrotechnology Research Institute), Jongmoo Kim (Korea Electrotechnology Research Institute), Byungchul Woo (Korea Electrotechnology Research Institute)
Abstract
This paper deals with the selection of the housing material of the contactless power supplier (CPS) used for the field winding power supply in wound field synchronous machine (WFSM). The housing of the CPS encloses the rotary transformer and the converter of secondary side. The housing prevents the damage of ferrite core in the rotary transformer and the secondary converter due to centrifugal force in the highest speed, 10,000 rpm.
Therefore, the housing should have been designed considering not only strengthen, but also lighten. Furthermore, efficiency is also one of important characteristics in power transfer to improve the whole system efficiency.
Taking account of aforementioned points, the stainless steel (SUS) and aluminum (Al), which are commonly used as housing materials, were under reviewed as CPS housing. After comparing the characteristic
of CPSs according to housing material in term of eddy current loss, thermal characteristic, and mechanical stability, the appropriate housing material is suggested. After that, experimental results deriving from tests are
presented to confirm the analysis results.
 
Keywords: finite element analysis; housing material; magnetic loss; thermal analysis
DOI: https://doi.org/10.4283/JMAG.2018.23.1.086
Full Text : PDF