![](/views/old_jom/img/center_up.gif)
Search
![](/views/old_jom/img/dot2.gif)
One-Ampere Conductor Method for Tubular Linear Induction Motor for Size Reduction of Primary Iron Core
Journal of Magnetics, Volume 16, Number 1, 31 Mar 2011, Pages 46-50
Abstract
This paper presents size reduction of primary iron core for tubular linear induction motor by improved winding configuration. Using one-ampere conductor method, magnetic field analysis of tubular linear induction motor for size reduction is conducted. Size reduction and improvement of air gap flux distribution is achieved by improved winding configuration, and analysis results are verified by finite element analysis (FEA) and experiments.
Keywords: analytical method; finite element analysis; magnetic flux density; one-ampere conductor method; tubular linear induction motor
DOI: 10.4283/JMAG.2011.16.1.046
Full Text : PDF
![](/views/old_jom/img/center_down.gif)