Design and Fabrication of 2-T Rotating Halbach Magnet for Magnetic Refrigerator

Journal of Magnetics, Volume 22, Number 1, 31 Mar 2017, Pages 65-68
Kwon Sang Ryu * (Korea Research Institute of Standards and Science (KRISS)), Seung Hoon Nahm (Korea Research Institute of Standards and Science (KRISS)), Jae Kap Jung (Korea Research Institute of Standards and Science (KRISS)), Seung-Wook Baek (Korea Research Institute of Standards and Science (KRISS))
Abstract
This paper reports simulation and evaluation of the magnetic flux density (MFD) of a rotating Halbach magnet (RHM) composed of a rotating inner Halbach cylinder (HC) and a fixed outer HC. We first chose the
dimension of a single HC, then determined the dimensions of an inner and outer HC to get MFD = 2 T. Simulation results were used to guide fabrication of an RHM; its magnetic field in the central axis direction
agreed well with simulated values.
 