Home 
Retrieve | Search
 
Issues
Retrieve
Home > Issues > Retrieve
 
Magnetic Shielding Effect on Halbach Cylinder used in Magnetic Refrigerators
Journal of Magnetics, Volume 19, Number 4, 31 Dec 2014, Pages 349-352
Un Bong Baek (Korea Research Institute of Standards and Science (KRISS)), Jong Suk Lee (Dept. of Precision Mechanical Engineering, Gangneung-Wonju National University), Seong-Cho Yu (Dept. of Physics, Chungbuk National University), Kwon-Sang Ryu * (Korea Research Institute of Standards and Science (KRISS))
Abstract

The system for producing magnetic field constitutes an important component of magnetic refrigerator. Many
researchers have directed significant effort to increase the magnetic field intensity, because the magnetocaloric effect at the Curie temperature increases with the power of 2/3 of the magnetic field. In this study, we report the simulation of the magnetic field intensity at polar axis of a Halbach cylinder (HC) by i) changing the length and thickness of the HC, ii) having with or without gap of the HC, and iii) surrounding the HC with a soft magnet shell, acting as a shielding. We simulated the field distribution of a HC with a finite size. Furthermore, the detailed numerical results of the magnetic field distribution and its dependence on shielding are presented in this study.


 

Keywords: magnetic refrigerator; Finite element method (FEM); Halbach cylinder (HC); magnetic shielding
DOI: http://dx.doi.org/10.4283/JMAG.2014.19.4.349
Full Text: PDF
 
Copyright(c) 2009 The Korean Magnetics Society All rights reserved. E-mail : komag@unitel.co.kr