Design and Comparison of Multistage Axial Flux Permanent Magnet Machines for Potable Generating Application
Journal of Magnetics, Volume 20, Number 4, 31 Dec 2015, Pages 413-420
Jiyoung Lee * (Korea Electro-technology Research Institute), Byounggun Park (Korea Electro-technology Research Institute), Byungchul Woo (Korea Electro-technology Research Institute)
Abstract

In this study, we present a comparison of multistage axial flux permanent-magnet machines (AFPMs) with
different topologies for use as 100 W-class portable generating systems. Three topologies were selected, and the maximum power density and high level of efficiency were achieved by following the response surface methodology (RSM) in the design. Three-dimensional finite element analysis (FEA) was used to conduct numerical experiments to obtain the optimum design using the RSM and suggest a proper configuration of the portable generating system.


 

Keywords: axial flux machine; finite element analysis; generator; permanent magnet machines; response surface methodology