Parametric Analysis of Tubular-Type Linear Magnetic Couplings with Halbach Array Magnetized Permanent Magnet by Using Analytical Force Calculation
Journal of Magnetics, Volume 21, Number 1, 31 Mar 2016, Pages 110-114
Chang-Woo Kim (Department of Electrical Engineering, Chungnam National University), Jang-Young Choi * (Department of Electrical Engineering, Chungnam National University)
Abstract

Magnetic couplings are widely used in various industrial applications because they can transmit magnetic force without any mechanical contact. In addition, linear couplings have many advantages. For example, they do not need to convert rotary motion to linear motion. This paper shows an analytical analysis of tubular type linear magnetic couplings (TLMCs) with a Halbach array magnetized permanent magnet (PM). An analytical method for magnetic fields owing to PMs is performed by using magnetic vector potential as well as Poisson and Laplace equations. Then, the magnetic force is calculated by using the Maxwell stress tensor. The analytical analysis results were compared with finite element method (FEM) results. In addition, we predicted the magnetic force characteristic according to design parameters such as the iron core thickness, inner PM thickness to -outer PM thickness ratio, PM segment ratio of the axial magnetized PM segment and radial magnetized PM segment, and various pole numbers.


 

Keywords: Parametric analysis; Halbach array; magnetic coupling; analytical method
DOI: http://dx.doi.org/10.4283/JMAG.2016.21.1.110