Efficient Fault Detection Method for a Degaussing Coil System Based on an Analytical Sensitivity Formula
Journal of Magnetics, Volume 18, Number 2, 30 Jun 2013, Pages 135-141
Nak-Sun Choi (Department of Electrical Engineering, Kyungpook National University), Dong-Wook Kim (Department of Electrical Engineering, Kyungpook National University), Chang-Seob Yang (The 6th R&D Institute-2, Agency for Defense Development), Hyun-Ju Chung (The 6th R&D Institute-2, Agency for Defense Development), Heung-Geun Kim (Department of Electrical Engineering, Kyungpook National University), Dong-Hun Kim * (Department of Electrical Engineering, Kyungpook National University)
Abstract

This paper proposes an efficient fault detection method for onboard degaussing coils which are installed to minimize underwater magnetic fields due to the ferromagnetic hull. To achieve this, the method basically uses field signals measured at specific magnetic treatment facilities instead of time-consuming numerical field solutions in a three-dimensional analysis space. In addition, an analytical design sensitivity formula and the linear property of degaussing coil fields is being exploited for detecting fault coil positions and assessing individual degaussing coil currents. Such peculiar features make it possible to yield fast and accurate results on the fault detection of degaussing coils. For foreseeable fault conditions, the proposed method is tested with a model ship equipped with 20 degaussing coils.


 

Keywords: diagnosis; electromagnetics; inverse problem; design sensitivity
DOI: http://dx.doi.org/10.4283/JMAG.2013.18.2.135
Full Text: PDF
 
Copyright(c) 2009 The Korean Magnetics Society All rights reserved. E-mail : komag@unitel.co.kr